1.J/A+A/555/A30/table2Count rate to flux conversion (for z=0) (151 rows)
2.J/A+A/555/A30/table3*K-correction as a function of z and Tx (Note) (20 rows)

 
Query by Constraints constraints help applied on Columns (Output Order: + - )
ShowSortJoin tables
more join
Column  Constraint Explain   (UCD)
  (ALL)recno  Record number assigned by the VizieR team. Should Not be used for identification. (meta.record)
  (1)NH 10+20cm-2 [0.1/100] Absorbing H column density (phys.columnDensity)
  (1)CR(0.5keV) 10-14J/m2Count rate for T=0.5keV (Note 1)   (arith.factor)
  (1)CR(1.0keV) 10-14J/m2Count rate for T=1.0keV (Note 1)   (arith.factor)
  (1)CR(1.5keV) 10-14J/m2Count rate for T=1.5keV (Note 1)   (arith.factor)
  (1)CR(2.0keV) 10-14J/m2Count rate for T=2.0keV (Note 1)   (arith.factor)
  (1)CR(3.0keV) 10-14J/m2Count rate for T=3.0keV (Note 1)   (arith.factor)
  (1)CR(4.0keV) 10-14J/m2Count rate for T=4.0keV (Note 1)   (arith.factor)
  (1)CR(5.0keV) 10-14J/m2Count rate for T=5.0keV (Note 1)   (arith.factor)
  (1)CR(6.0keV) 10-14J/m2Count rate for T=6.0keV (Note 1)   (arith.factor)
  (1)CR(7.0keV) 10-14J/m2Count rate for T=7.0keV (Note 1)   (arith.factor)

ALL cols
    
 (i)indexed column
  (1)CR(8.0keV) 10-14J/m2Count rate for T=8.0keV (Note 1)   (arith.factor)
  (1)CR(9.0keV) 10-14J/m2Count rate for T=9.0keV (Note 1)   (arith.factor)
  (1)CR(10.keV) 10-14J/m2Count rate for T=10.0keV (Note 1)   (arith.factor)
  (1)HR  Hardness ratio (H-S)/(H+S) in 0.5-2.0keV and 0.1-0.4keV bands (Note 2)   (phot.flux;em.X-ray.soft;arith.ratio)
  (2)z   [0.025/0.5] Redshift (src.redshift)
  (2)K(0.5keV)  K-correction factor for T=0.5keV (Note 1)   (arith.factor;phot.mag)
  (2)K(1.0keV)  K-correction factor for T=1.0keV (Note 1)   (arith.factor;phot.mag)
  (2)K(1.5keV)  K-correction factor for T=1.5keV (Note 1)   (arith.factor;phot.mag)
  (2)K(2.0keV)  K-correction factor for T=2.0keV (Note 1)   (arith.factor;phot.mag)
  (2)K(3.0keV)  K-correction factor for T=3.0keV (Note 1)   (arith.factor;phot.mag)
  (2)K(4.0keV)  K-correction factor for T=4.0keV (Note 1)   (arith.factor;phot.mag)
  (2)K(5.0keV)  K-correction factor for T=5.0keV (Note 1)   (arith.factor;phot.mag)
  (2)K(6.0keV)  K-correction factor for T=6.0keV (Note 1)   (arith.factor;phot.mag)
  (2)K(7.0keV)  K-correction factor for T=7.0keV (Note 1)   (arith.factor;phot.mag)
  (2)K(8.0keV)  K-correction factor for T=8.0keV (Note 1)   (arith.factor;phot.mag)
  (2)K(9.0keV)  K-correction factor for T=9.0keV (Note 1)   (arith.factor;phot.mag)
  (2)K(10.keV)  K-correction factor for T=10.0keV (Note 1)   (arith.factor;phot.mag)

ALL cols
    