VizieR

CfA VizieR . ADAC VizieR . Cambridge (UK) VizieR . IUCAA VizieR . INASAN VizieR .

VizieR

  
J/A+A/567/A89
  Swift X-ray Telescope Cluster Survey. II. (Tozzi+, 2014)
Post annotation
img(gal)
1.J/A+A/567/A89/table2Results of X-ray spectral analysis (46 rows)

 
Query by Constraints constraints help applied on Columns (Output Order: + - )
ShowSortColumn  Constraint Explain   (UCD)
  recno  Record number assigned by the VizieR team. Should Not be used for identification. (meta.record)
  SWXCS (char) SWXCS designation (JHHMMSS+DDMM.m) (meta.id;meta.main)
  Rext arcmin Radius of the circular region used for spectroscopic analysis (phys.angSize;obs.field)
  kT keV Temperature directly obtained from the spectral analysis (phys.temperature)
  E_kT keV Error on kT (upper value) (stat.error;stat.max)
  e_kT keV Error on kT (lower value) (stat.error;phys.energy)
  kTc keV Temperature corrected for fitting bias (phys.temperature)
  E_kTc keV Error on kTc (upper value) (stat.error;stat.max)
  e_kTc keV Error on kTc (lower value) (stat.error)
  l_Z (char) Limit flag on Z (meta.code.error;src.redshift)
  Z Sun Iron abundance directly obtained from the spectral analysis (phys.abund.Fe)

ALL cols
    
 (i)indexed column
  E_Z Sun (n) Error on Z (upper value) (stat.error;stat.max)
  e_Z Sun (n) Error on Z (lower value) (stat.error;src.redshift)
  l_Zc (char) Limit flag on Zc (meta.code.error;phys.abund.Z)
  Zc Sun (n) Iron abundance corrected for the fitting bias (phys.abund.Z)
  E_Zc Sun (n) Error on Zc (upper value) (stat.error;stat.max)
  e_Zc Sun (n) Error on Zc (lower value) (stat.error;pos.cartesian.z)
  FS mW/m2 Soft (0.5-2keV) band flux measured within Rext (phot.flux;em.X-ray)
  LS 10+37W X-ray luminosity in the soft (0.5-2keV) band measured within Rext (in 1044erg/s) (phys.luminosity;em.X-ray)
  Lbol 10+37W Bolometric X-ray luminosity measured within Rext (in 1044erg/s) (phys.luminosity)
  Cts ct Net counts in the soft (0.5-2keV) band (phot.count;em.X-ray)
  R500l kpc Estimated R500 in kpc (Note 1)   (phys.size.radius)
  e_R500l kpc rms uncertainty on R500 in arcmin (stat.error)
  R500 arcmin Estimated R500 in arcmin (Note 1)   (phys.size.radius)
  e_R500 arcmin rms uncertainty on R500 in arcmin (stat.error)
  LS2 10+37W Estinated X-ray luminosity in the 0.5-2keV band within R500 (in 1044erg/s) (phys.luminosity;em.X-ray)
  E_LS2 10+37W Error on LS2 (upper value) (stat.error;stat.max)
  e_LS2 10+37W Error on LS2 (lower value) (stat.error)
  Lbol2 10+37W Estimated bolometric X-ray luminosity within R500 (in 1044erg/s) (phys.luminosity)
  E_Lbol2 10+37W Error on Lbol2 (upper value) (stat.error;stat.max)
  e_Lbol2 10+37W Error on Lbol2 (lower value) (stat.error)

ALL cols
    
(n) indicates a possible blank or NULL column(i)indexed column
Adapt form
Display your selection only Reset to default columns
usage  Display UCD1+    UCD1  
elapse time 1

Cite/acknowledge VizieR catalogue
Rules of usage of VizieR data

© UDS/CNRS

Contact