VizieR

CfA VizieR . ADAC VizieR . Cambridge (UK) VizieR . IUCAA VizieR . INASAN VizieR .

VizieR

Simple TargetList Of TargetsFast Xmatch with large catalogs or Simbad
Target Name (resolved by Sesame) or Position:
Target dimension:
NB: The epoch used for the query is the original epoch of the table(s)Radius Box size

  
J/ApJ/864/150
  Black holes & neutron stars in nearby galaxies (Vulic+, 2018)
Post annotation
img(gal)
1.J/ApJ/864/150/table3NuSTAR point source properties (128 rows)

 
Query by Constraints constraints help applied on Columns (Output Order: + - )
ShowSortColumn  Constraint Explain   (UCD)
  recno  Record number assigned by the VizieR team. Should Not be used for identification. (meta.record)
  Gal (char) Galaxy name (meta.id.part;meta.main)
  ID   [1/25] Point source identifier within Gal (Note 1)   (meta.id.part;meta.main)
  RAJ2000 deg (i) [11.8/214] Right ascension (J2000) (pos.eq.ra;meta.main)
  DEJ2000 deg (i) [-67/71] Declination (J2000) (pos.eq.dec;meta.main)
  CR4-6keV 10-4ct/s [0.39/1559] Soft (4-6keV) count rate (Note 2)   (phot.count;em.X-ray)
  E_CR4-6keV 10-4ct/s [0/37] Upper uncertainty on CR4-6keV (Note 3)   (stat.error;stat.max)
  e_CR4-6keV 10-4ct/s [0/38] Lower uncertainty on CR4-6keV (Note 3)   (stat.error)
  CR6-12keV 10-4ct/s [0.79/2202] Medium (6-12keV) count rate (Note 2)   (phot.count;em.X-ray)
  E_CR6-12keV 10-4ct/s [0/20] Upper uncertainty on CR6-12keV (Note 3)   (stat.error;stat.max)
  e_CR6-12keV 10-4ct/s [0/35] Lower uncertainty on CR6-12keV (Note 3)   (stat.error)

ALL cols
    
 (i)indexed column
  CR12-25keV 10-4ct/s [0.39/476] Hard (12-25keV) count rate (Note 2)   (phot.count;em.X-ray)
  E_CR12-25keV 10-4ct/s [0/14] Upper uncertainty on CR12-25keV (Note 3)   (stat.error;stat.max)
  e_CR12-25keV 10-4ct/s [0/14] Lower uncertainty ob CR12-25keV (Note 3)   (stat.error)
  CR4-25keV 10-4ct/s [2/4895] Full (4-25keV) count rate (Note 2)   (phot.count;em.X-ray)
  E_CR4-25keV 10-4ct/s [0/52] Upper uncertainty on CR4-25keV (Note 3)   (stat.error;stat.max)
  e_CR4-25keV 10-4ct/s [0/61] Lower uncertainty on CR4-25keV (Note 3)   (stat.error)
  HR1   [-0.45/0.95] Hardness ratio HR1=(M-S)/(M+S) (Note 4)   (phot.flux;arith.ratio)
  E_HR1   [0/0.93] Upper uncertainty on HR1 (stat.error;stat.max)
  e_HR1   [0/0.42] Lower uncertainty on HR1 (stat.error)
  HR2   [-0.93/0.41] Hardness ratio HR2=(H-M)/(H+M) (Note 4)   (phot.flux;arith.ratio)
  E_HR2   [0/0.75] Upper uncertainty on HR2 (stat.error;stat.max)
  e_HR2   [0/0.27] Lower uncertainty on HR2 (stat.error)
  LX 10+31W [0.12/366] 4-25keV X-ray luminosity in 1038erg/s (4) (Note 5)   (phys.luminosity;em.X-ray)
  E_LX 10+31W [0/4] Upper uncertainty on LX (stat.error;stat.max)
  e_LX 10+31W [0/5] Lower uncertainty on LX (stat.error)
  Type (char) Source type (BH=47 occurrences or NS=43 occurrences) (src.class)
  State (char) State (Note 6)   (src.class)

ALL cols
    
 (i)indexed column
Adapt form
Display your selection only Reset to default columns
usage  Display UCD1+    UCD1  
elapse time 0

Cite/acknowledge VizieR catalogue
Rules of usage of VizieR data

© UDS/CNRS

Contact