VizieR

CfA VizieR . ADAC VizieR . Cambridge (UK) VizieR . IUCAA VizieR . INASAN VizieR .

VizieR

  
J/ApJ/914/47
  ISS/NICER X-ray observations of eta Car (Kashi+, 2021)
Post annotation
  
1.J/ApJ/914/47/table2Best-fit model parameters to the 5-10keV NICER X-ray spectra of Eta Car between July 2017 and July 2020 and their 90% confidence values (233 rows)

 
Query by Constraints constraints help applied on Columns (Output Order: + - )
ShowSortColumn  Constraint Explain   (UCD)
  recno  Record number assigned by the VizieR team. Should Not be used for identification. (meta.record)
  Date s (n)NICER Observation Date, UT, ISO-8601 (time.epoch;obs)
  ObsID  Unique observation number (meta.id;obs)
  l_NH (char) Limit flag on NH (Note G1)   (meta.code.error)
  NH 10+22cm-2(n) [8/430] Absorbing column density (phys.columnDensity)
  E_NH 10+22cm-2(n) [4/293] Upper 90% confidence interval on NH (stat.error;stat.max)
  e_NH 10+22cm-2(n) [4/78] Lower 90% confidence interval on NH (stat.error)
  l_kT (char) Limit flag on kT (Note G1)   (meta.code.error;phys.energy)
  kT keV (n) [0.3/8] Plasma energy (phys.temperature;em.X-ray)
  E_kT keV (n) [0.2/13.7] Upper 90% confidence interval on kT (stat.error;stat.max)
  e_kT keV (n) [0.1/5.1] Lower 90% confidence interval on kT (stat.error;phys.energy)

ALL cols
    
(n) indicates a possible blank or NULL column(i)indexed column
  l_Fe (char) Limit flag on Fe (Note G1)   (meta.code.error;phys.abund.Fe)
  Fe [Sun] (n) [0.13/6.72] Iron abundance, relative to Solar (phys.abund)
  E_Fe [Sun] (n) [0.04/2.3] Upper 90% confidence interval on Fe (stat.error;stat.max)
  e_Fe [Sun] (n) [0.04/0.7] Lower 90% confidence interval on Fe (stat.error;phys.abund.Fe)
  logEM [cm-3] [56.47/60.24] Log of the emission measure (phys.emissMeasure)
  E_logEM [cm-3] [0.07/3.2] Upper 90% confidence interval on logEM (stat.error;stat.max)
  e_logEM [cm-3] [0.05/2.3] Lower 90% confidence interval on logEM (stat.error)
  l_Flux (char) Limit flag on Flux (Note G1)   (meta.code.error;phot.flux)
  Flux 10-14W/m2(n) [0.03/14] Observed flux in the 5-10keV band, 10–11erg/s/cm2 (Note G2)   (phot.flux;em.X-ray.medium)
  E_Flux 10-14W/m2(n) [0.1/28] Upper 90% confidence interval on Flux (stat.error;stat.max)
  e_Flux 10-14W/m2(n) [0.03/10] Lower 90% confidence interval on Flux (stat.error;phot.flux)
  IntFlux 10-14W/m2 [0.1/56] Intrinsic (i.e., unabsorbed) flux in the 5-10keV band, 10–11erg/s/cm2 (Note G2)   (phot.flux;em.X-ray.medium)
  E_IntFlux 10-14W/m2 [0.1/50] Upper 90% confidence interval on Flux (stat.error;stat.max)
  e_IntFlux 10-14W/m2 [0.08/49] Lower 90% confidence interval on Flux (stat.error)
  chi2   [0.3/2.94] Reduced χ^2 value associated with the best fit model (stat.fit.chi2)

ALL cols
    
(n) indicates a possible blank or NULL column(i)indexed column
Adapt form
Display your selection only Reset to default columns
usage  Display UCD1+    UCD1  
elapse time 0

Cite/acknowledge VizieR catalogue
Rules of usage of VizieR data

© UDS/CNRS

Contact