VizieR

CfA VizieR . ADAC VizieR . Cambridge (UK) VizieR . IUCAA VizieR . INASAN VizieR .

VizieR

  
J/ApJS/233/17
  Swift/BAT AGN spectroscopic survey. V. X-ray data (Ricci+, 2017)
Post annotation
img(gal)
1.J/ApJS/233/17/table9Spectral parameters obtained with the torus model (75 rows)

 
Query by Constraints constraints help applied on Columns (Output Order: + - )
ShowSortColumn  Constraint Explain   (UCD)
  recno  Record number assigned by the VizieR team. Should Not be used for identification. (meta.record)
  SWIFT (char) Swift-BAT 70-month hard X-ray survey source name (JHHMM.m+DDMMA) (meta.id;meta.main)
  l_thetaOA (char) [<≥ ] Limit flag for thetaOA (meta.code.error)
  thetaOA deg [31/82] Half-opening angle of the torus (pos.posAng)
  E_thetaOA deg (n) Upper error (90%) for thetaOA (stat.error;stat.max)
  e_thetaOA deg (n) [2/25] Lower error (90%) for thetaOA (stat.error)
  f_thetaOA (char) [f] Flag on thetaOA (Note G1)   (meta.code)
  logNH-tor [cm-2] [23.3/25.6] Log of the column density of the neutral obscuring material obtained with the torus model (phys.columnDensity;meta.modelled)
  b_logNH-tor [cm-2] [22.9/25.1] Lower bound of the 90% confidence interval for logNH-tor (stat.fit.param)
  B_logNH-tor [cm-2] [23.4/26] Upper bound of the 90% confidence interval for logNH-tor (Note 1)   (stat.fit.param)
  Gamma-tor   [1.2/3] Photon index of the primary X-ray continuum obtained with the torus model (spect.index)

ALL cols
    
(n) indicates a possible blank or NULL column(i)indexed column
  E_Gamma-tor  Upper error (90%) for Gamma-tor (stat.error;stat.max)
  e_Gamma-tor   [0.01/1] Lower error (90%) for Gamma-tor (stat.error)
  l_fscatt-tor (char) [≤ ] Upper limit Flag for Gamma-tor (meta.code.error)
  fscatt-tor % (n) [0.01/18.3] Fraction of scattered radiation obtained with the torus model (stat.fit.param)
  E_fscatt-tor % (n) [0.01/20] Upper error (90%) for fscatt-tor (stat.error;stat.max)
  e_fscatt-tor % (n) Lower error (90%) for fscatt-tor (stat.error)
  Temp-tor keV (n) [0.03/1.3] Temperature of the thermal plasma component obtained with the torus model (phys.temperature;meta.modelled)
  E_Temp-tor keV (n) [0.01/8] Upper error (90%) for Temp-tor (stat.error;stat.max)
  e_Temp-tor keV (n) Lower error (90%) for Temp-tor (stat.error)
  Temp2-tor keV (n) [0.6/1.1] Temperature of the second thermal plasma component obtained with the torus model (phys.temperature;meta.modelled)
  E_Temp2-tor keV (n) [0.03/0.4] Upper error (90%) for Temp2-tor (stat.error;stat.max)
  e_Temp2-tor keV (n) Lower error (90%) for Temp2-tor (stat.error)
  CBAT-tor  (n) [0.3/8] Cross-calibration constant obtained with the torus model (phot.calib;arith.zp)
  E_CBAT-tor  (n) [0.08/9] Upper error (90%) for CBAT-tor (stat.error;stat.max)
  e_CBAT-tor  (n) Lower error (90%) for CBAT-tor (stat.error)
  f_CBAT-tor (char) [f] Flag for CBAT-tor (Note G1)   (meta.code)
  Stat-tor   [6/1958] Value of the statistic obtained with the torus model (stat.fit.param)
  DOF-tor   [12/1463] Number of degrees of freedom for the torus model (meta.number)

ALL cols
    
(n) indicates a possible blank or NULL column(i)indexed column
Adapt form
Display your selection only Reset to default columns
usage  Display UCD1+    UCD1  
elapse time 0

Cite/acknowledge VizieR catalogue
Rules of usage of VizieR data

© UDS/CNRS

Contact